Home > Products > Process Calibrator > Thermocouple Calibrator VA710

Thermocouple Calibrator VA710

Thermocouple Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple instrument.
Thermocouple Calibrator can measure or simulate 8 types of difference Thermocouple (℃ or℉), and measure or simulate the millivolt. But it could not use to measurement or source at a same time.

Send Inquiry

Description

    Product Features:

    • Measure or simulate the millivolt and 8 types of Thermocouple (℃ or ℉)
    • Large 5 digit LCD with full angle
    • High Accuracy Max.up to 0.3℃ and 0.025% mV
    • With standard jack for external power supply
    • Maximum voltage applied between any jack and earth ground or between any two jack:30V
    • Storage temperature: -40℃~60℃
    • Operating temperature: 0℃~50℃
    • Operating altitude: 3000 meters maximum
    • Temperature coefficient: ±0.02%/℃ on 0℃~18℃ and 28℃~50℃
    • Relative humidity: 95% up to 30℃,75% up to 40℃,45% up to 50℃
    • Shock: Random 2g, 5Hz to 500Hz
    • Safety: 1 meter drop test
    • Fuse: F 0.125A/250V
    • Power requirements: 6 x AAA 1.5V Battery
    • Size: 205mm×98mm×46mm
    • Weight: 472 g (include battery)

    Product Parameters:

    VA710
    Thermocouple Type J,K,T,E,R,S,B,N
    Temperature Resolution 0.1/0.1
    Temperature error ±(0.3+10μV)
    Voltage range  -10mV~100mV
    Voltage resolution 0.01mV
    Voltage accuracy ±(0.025%+2)
    LCD Size 64×42 mm
    Product Size 205 x 97 x 45 mm
    Weight ~472 g (include battery)

    Application and After-Sales Service:

    Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple instrument.

    ACCESSORIES:

    Delivered with the multimeter:
    2 pcs Thermocouple plugs (no wire), 6 * AAA 1.5V battery, user’s manual.
    General Maintenance
    Cleaning
    Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.
    Calibration
    Calibrate your calibrator once a year to ensure that it performs according to its specifications.
    Replacing the Battery
    Please change the battery when the LCD indicates
    Turn off the power of the Calibrator, When you change the battery, and screw off the breechblock on the battery cabinet cover, then take off it and instead the fresh battery.
    Replacing a Fuse
    Warning!
    To avoid personal injury or damage to the calibrator, use only a 0.125A 250V fast fuse.
    In the thermocouple input mode, if ‘OL’ does not appears on LCD with no thermocouple input, the fuse is probably blown. A new fuse should be used.
    Connect wire
    Use the accessories thermocouple plug to make the difference plug connect wire which you want.